Alken-Murray logo header

Dosage for Alken Clear-Flo 7110 - Regular Strength

  < 50 ppm of Ammonia

 > 50 ppm of Ammonia

Product volume in this table is in liters

1000 cubic meters
 Day 1  Day 2

 Days 3 - 7

 Days 8 - 14

 Days 15 +
 

Day 1 

 Day 2

 Days 3 - 7 

 Days 8 - 14

 Days 15 +

 1.0

 30

 15

 11

 7.6

 3.0
 

 45

 30

 11

 7.6

 3.0

 1.9

 61

30

 19

 9.1

 3.4
 

 91

 45

 27

 10

 3.8

 2.8

 91

 45

 27

 10

 3.8
 

 125

 61

 38

 12

 4.9

 3.8

 125

 61

 38

 12

 4.9
 

 167

 91

45 

 18

 7.2

 5.7

 167

 68

 42

 13

 5.3
 

 212

 106

 53

 21

 8.3

 7.6

 227

 76

 49

 15

 6.1
 

 257

 121

 57

 28

 11

 11

 333

 106

 53

 22

 9.1
 

 424

 167

 61

 35

 14

 15

 500

 121

 57

 30

 12
 

 590

 182

 76

 45

 18

 19

 666

 167

 61

 42

 17
 

 757

 272

 95

 57

 30

Dosage for Alken Clear-Flo 7110 - 50x

  < 50 ppm of Ammonia

 > 50 ppm of Ammonia

Product volume in this table is in milliliters, unless specified in liters

1000 cubic meters
 Day 1  Day 2

 Days 3 - 7

 Days 8 - 14

 Days 15 +
 

Day 1 

 Day 2

 Days 3 - 7 

 Days 8 - 14

 Days 15 +

 1.0

 620

 300

 210

 145

 60
 

 920

 620

 210

 150

 60

 1.9

 1.2 L

620

 385

 175

 75
 

 1.9 L

 950

 560

 210

 90

 2.8

 1.9 L

 950

 560

 210

 90
 

 2.4 L

 1.2 L

 770

 235

 95

 3.8

 2.5 L

 1.2 L

 770

 235

 95
 

 3.3 L

 1.9 L

890

 350

 140

 5.7

 3.3 L

 1.5 L

 900

 300

 120
 

 4.2 L

 2.1 L

 1.0 L

 415

 160

 7.6

 4.5 L

 1.9 L

 975

 350

 140
 

 5.7 L

2.4 L 

 1.1 L

 560

 270

 11

 7.6 L

 2.1 L

 1.0 L

 440

 180
 

 9.5 L

 3.3 L

 1.2 L

 700

 300

 15

 11.4 L

 2.5 L

 1.1 L

 590

 240
 

 13.0 L

 3.6 L

 1.5 L

 890

 360

 19

 13 L

 3.3 L

 1.2 L

 800

 320
 

 15.0 L

 5.7 L

 1.9 L

 1.1 L

 440

 

Most systems will respond within 14 days of treatment, typically within 3 to 6 days. If the program fails to produce significant results within 2 weeks, contact Valerie or Claudia.
Monitoring of the treated system should minimally include ammonia, nitrite, nitrate, dissolved oxygen and pH. Additional parameters recommended for monitoring include TKN, total alkalinity, and effluent BOD5. This data is indispensible for troubleshooting and qualifying applications. Be sure to maintain sufficient alkalinity to prevent pH drop below 7.0.
The data included in these tables are based on test information obtained by Alken-Murray Corporation. The data are believed to be reliable, but do not imply warranty or performance guarantee.We recommend that the user determine performance by testing on his own installation with our bench test procedure. ALKEN CLEAR-FLO is a registered trademark of Alken-Murray Corporation.

E-mail: clearflo@alken-murray.com

Alken-Murray banner link to homepage